1.1 conditions: perform on (or off) moves lowest energy (that is, the load voltage DC2 ~ 3 V), action in place, and then perform a reverse action to close (or open) the highest energy (that is, the load voltage DC4.2 V to 6 V) action in place.
1.2 Requirement: repeatedly in 5 ~ 10 times
1.3 Scope: all inspection
1.4 Instruments: homemade special testing table
1.5 Results: reliable and in place
1.6 Note: (1) motor valve under the condition of energy change is bigger, also can ensure the reliable operation (2) the machine jammed
2¡¢Stable under normal working conditions, the movement detection2.1 Condition: DC5V execution time: 2/10-4/10 of a second condition DC3V execution time 3/10-5/10 of a second
2.2 Requirements: positive and negative to the power supply, switching the 10 ~ 20 times
2.3 Scope: all inspection
2.4 Equipment: automatic IC card dedicated valve test bench
2.5 Results: the reliable, stable and in place
3¡¢Water leakage test3.1 Conditions: charging DC3V make motor valve closed, add about 10 kpa pressure, and valve sealing mouth immersed in water
3.2 Requirements: careful inspection body sealing mouth
3.3 Scope: all inspection
3.4 Leak detection instrument: homemade water type test bed
3.5 Results: no leakage
4¡¢Resistance to life testing4.1 Condition: electric DC3.0 ~ 5.0 V execution time 2/10-5/10 of a second
4.2 Requirements: set up more than 20000 times
4.3 Scope: sampling (2-3 ¡ë)
4.4 Equipment: automatic IC card valve test bench
4.5 Results: reliable, stable and in place
5¡¢Controller with horse detection5.1 Simulated test conditions: choose matching controller
5.2 Requirements: movement 3 ~ 5 times
5.3 Scope: sampling (5-10%), or the whole (the buyer provide control circuit)
5.4 Instruments: auxiliary controller
5.5 Results: reliable, stable and in place
6¡¢Corrosion test6.1 Condition: the valve in the concentration of 3 ~ 5) salt spray tester set within 36 hours
6.2 Request: more than 36 hours
6.3 Scope: sampling (3-5 ¡ë)
6.4 Instruments: special salt spray testing machine
6.5 Results: the action of the valve is in good condition, is normal
7¡¢High and low temperature test7.1 Conditions: in the valve box, high and low temperature testing machine set low temperature 25 ¡æ after an hour out immediately detect actions; Set high temperature + 65 ¡æ, remove immediately detect movement in an hour
7.2 Requirement: the valve is in good condition, action is normal
7.3 Scope: sampling (3-5 ¡ë)
7.4 Special equipment: high and low temperature test equipment
7.5 Results: the action of the valve is in good condition, is normal
8¡¢To withstand test inspection8.1 Condition: the valve from the ground (common concrete) 80 ~ 100 cm free fall
8.2 Requirements: action of the valve without damage, is normal
8.3 Scope: sampling (3-5 ¡ë)
8.4 Instruments: artificial
8.5 Results: the action of the valve is in good condition, is normal
9¡¢Appearance test9.1 Requirement: the body, smooth surface, no burrs brush motor lead no damage, fitting the conform to the requirements of the assembly
9.2 Scope: all inspection
9.3 Results: the qualified